Andrey Skvortsov <andrej.skvortzov@gmail.com> [Mon, 18 Apr 2016 18:51:59 +0300] rev 1477
fix issue, when structure data type with array field is created
Traceback (most recent call last):
File "editors/DataTypeEditor.py", line 669, in ElementArrayTypeFunction
self.RefreshTypeInfos()
File "editors/DataTypeEditor.py", line 761, in RefreshTypeInfos
self.Controler.SetDataTypeInfos(self.TagName, infos)
File "PLCControler.py", line 2075, in SetDataTypeInfos
array.baseType.setcontent(PLCOpenParser.CreateElement(
AttributeError: 'lxml.etree._Element' object has no attribute 'setcontent'
Andrey Skvortsov <andrej.skvortzov@gmail.com [Mon, 18 Apr 2016 18:48:15 +0300] rev 1476
fixes sometimes happened error during project compilation
Traceback (most recent call last):
File "./Beremiz.py", line 1229, in run_with_except_hook
run_old(*args, **kw)
File
"/home/developer/WorkData/PLC/beremiz/beremiz/util/ProcessLogger.py",
line 68, in run
self.endcallback(self.Proc.pid, err)
File
"/home/developer/WorkData/PLC/beremiz/beremiz/util/ProcessLogger.py",
line 169, in finish
if self.timeout: self.timeout.cancel()
AttributeError: ProcessLogger instance has no attribute 'timeout'
mjsousa [Wed, 21 Oct 2015 15:00:32 +0100] rev 1475
merge
mjsousa [Sat, 06 Dec 2014 19:31:51 +0000] rev 1474
Use '-p' command line option when running matiec (iec2c)
mjsousa [Wed, 26 Nov 2014 16:05:14 +0000] rev 1473
Add command line option '-l' when calling matiec
mjsousa [Wed, 12 Nov 2014 17:36:27 +0000] rev 1472
merge
mjsousa [Tue, 08 Jul 2014 18:01:33 +0100] rev 1471
merge
mjsousa [Fri, 06 Jun 2014 18:30:49 +0100] rev 1470
merge
mjsousa [Mon, 26 May 2014 14:44:03 +0100] rev 1469
Update __SET_VAR() macros to reflect changes made to matiec
Edouard Tisserant [Fri, 19 Jun 2015 23:36:35 +0200] rev 1468
Merged
Edouard Tisserant [Fri, 19 Jun 2015 22:36:35 +0200] rev 1467
Merged
Edouard Tisserant [Fri, 19 Jun 2015 21:56:35 +0200] rev 1466
Fixed win32 build warning caused by leftover debug code
Edouard Tisserant [Fri, 19 Jun 2015 21:36:35 +0200] rev 1465
Fixed win32 runtime crashing when attempting to log before errors before PLC start. Added pictures to wxHMI and fixed it so that it loads on windows as well
Edouard Tisserant [Fri, 19 Jun 2015 11:36:35 +0200] rev 1464
Fixed canfestival extension own path resolution
Edouard Tisserant [Fri, 19 Jun 2015 09:34:18 +0200] rev 1463
Changed runtime's global PLCID to PLC_ID, working around redefinition in windoze' headers.
Edouard Tisserant [Thu, 18 Jun 2015 15:22:43 +0200] rev 1462
Extended wxHMI test
Edouard Tisserant [Thu, 18 Jun 2015 11:36:35 +0200] rev 1461
Added wxHMI test
Edouard Tisserant [Mon, 15 Jun 2015 10:19:52 +0200] rev 1460
merged forgotten changesets
Edouard Tisserant [Sat, 14 Mar 2015 14:51:39 +0100] rev 1459
Added log message when RETAIN memory not valid
Edouard Tisserant [Sat, 14 Mar 2015 11:32:23 +0100] rev 1458
Fixed leftover typo
Edouard Tisserant [Fri, 13 Mar 2015 22:36:52 +0100] rev 1457
Added PLCID variable accessible from C side, set with binarie's MD5. Added retain init and cleanup calls. Extended tests/python to test PLCID
Edouard Tisserant [Fri, 13 Mar 2015 17:19:58 +0100] rev 1456
Splitted plc_Xenomai_main.c to enable further customization
Ronan Bignaux <r.bignaux@rbi.io> [Fri, 03 Apr 2015 17:08:13 +0200] rev 1455
add pyrossl client side
Edouard Tisserant [Tue, 24 Mar 2015 14:06:28 +0100] rev 1454
fixed build of some tests