Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 19:25:58 +0300] rev 1597
always load existing PLC program from the working directory
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 19:24:16 +0300] rev 1596
stop PLC before unloading
This fixes segmentation fault if service was quit without stopping it.
It has happened if Beremiz service was quit using taskbar icon or by
closing Beremiz IDE (in case of autostarted local service).
In second case to trigger the bug following step has to be done:
1. Open Beremiz IDE
2. Open project, compile and connect to LOCAL:// runtime
3. Transfer and start the PLC program
4. Open other project without disconneting the PLC runtime
5. Close Beremiz IDE
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:32:34 +0300] rev 1595
add internatialization support for Beremiz_service.py
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:25:37 +0300] rev 1594
fix issue with changing annonced Pyro service name via taskbar icon
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:23:59 +0300] rev 1593
don't crash on trying to change IP interface for Beremiz_service using taskbar icon if IP wasn't previously
By default IP is not set (None) and service listen only on localhost interface.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:15:04 +0300] rev 1592
start/stop from taskbar icon only if PLC is stopped/started
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 17:54:41 +0300] rev 1591
close Pyro socket after daemon stop
without that socket port is open after daemon shutdown.
As a result if you restart daemon with new settings (service name, for example),
it can't listen on already used port and opens the next free TCP port
regardless of requested settings.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 17:51:20 +0300] rev 1590
add python-wxgtk3.0 support to Beremiz_service.py
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 02 Dec 2016 17:48:26 +0300] rev 1589
make about dialog on Windows not so big
It was automatically expanded to place description in one line.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 01 Dec 2016 18:31:10 +0300] rev 1588
update Russian translation
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 01 Dec 2016 18:30:34 +0300] rev 1587
add i18n to PLC status
Extra strings are added to the code to make mki18n.py to find these
strings in source files and put them into i18n/messages.pot.
Sergey Surkov <surkovsv93@gmail.com> [Thu, 01 Dec 2016 16:59:16 +0300] rev 1586
remove clear and reset execution order buttons in popup menu in SFC and LD viewers.
Sergey Surkov <surkovsv93@gmail.com> [Thu, 01 Dec 2016 16:52:28 +0300] rev 1585
fix initial(equal to the min) number of sequences in SFC Divergence dialog.
Sergey Surkov <surkovsv93@gmail.com> [Thu, 01 Dec 2016 16:40:49 +0300] rev 1584
make only correct blocks(by IEC 61131-3 standard) available in wire popup menu in SFC Viewer
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 30 Nov 2016 14:27:18 +0300] rev 1583
move EnhancedStatusBar.py to the right location