Andrey Skvortsov <andrej.skvortzov@gmail.com> [Tue, 04 Apr 2017 11:34:31 +0300] rev 1671
add function block to variable panel if fb is added using toolbar
Closes #25
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Tue, 28 Mar 2017 19:48:51 +0300] rev 1670
enable to write SFC transition in IL
This commit reverts previous commit 3f3d97be9a9f.
Because the fix for the matiec problem is already upstream
(https://bitbucket.org/mjsousa/matiec/commits/ce026aee03e00c0790948a18bd7b35805457da81)
Surkov Sergey <surkovsv93@gmail.com> [Tue, 28 Mar 2017 17:09:31 +0300] rev 1669
fix debug button and variable tree generate for actions and transitions in POU instance variable panel
for 'None' type instances(Python POU's, Native, SVGUI, user-defined pou's, etc.) debug button will be disabled. If action or transition instances have opened in instance variable panel,variables from main POU will be loaded. When user press debug button on variable instance in action or transition, instance path to main POU will be used, because all variables of action or transition in instance variable tree belong to main POU.
Surkov Sergey <surkovsv93@gmail.com> [Tue, 28 Mar 2017 11:31:05 +0300] rev 1668
clear variable location cell in variable panel, if variable class or type changed
if variable class is not local or global, or variable type is not locatable, variable location cell would be empty and read-only
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Mon, 27 Mar 2017 18:03:26 +0300] rev 1667
runtime is licensed under LGPLv2.1
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Mon, 27 Mar 2017 17:40:56 +0300] rev 1666
make command line help message for Beremiz more verbose
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Tue, 21 Mar 2017 18:01:09 +0300] rev 1665
fix typos and small errors in Russian translation
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 10 Mar 2017 19:17:43 +0300] rev 1664
merge Beremiz launcher support
Closes #13
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 10 Mar 2017 19:12:43 +0300] rev 1663
rename BeremizIDELauncher.py to Beremiz.py
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 10 Mar 2017 17:36:18 +0300] rev 1662
rename Beremiz.py to BeremizIDE.py
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 10 Mar 2017 17:09:48 +0300] rev 1661
wrap Beremiz startup code into separate launcher class
this should make it easier to make customized version of Beremiz IDE.
It's easy to add own splash, change version, add/disable extensions
and many other things.
For example:
[----- MyBeremiz.py ------]
#!/usr/bin/env python
from BeremizIDELauncher import BeremizIDELauncher
class MyBeremizIDELauncher(BeremizIDELauncher):
def __init__(self):
BeremizIDELauncher.__init__(self)
self.splashPath = self.Bpath("", "splash.png")
def ShowSplashScreen(self):
# comment next line to disable splash entirely
BeremizIDELauncher.ShowSplashScreen(self)
# change version
import version
version.app_version = "3.141-rc52"
def LoadExtensions(self):
# add/modifine list of extensions
# in self.extensions
BeremizIDELauncher.LoadExtensions(self)
if __name__ == '__main__':
beremiz = MyBeremizIDELauncher()
beremiz.Start()
[-------------------------]
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Fri, 10 Mar 2017 18:42:24 +0300] rev 1660
dynamically increase size of dialog window for editing comment block
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 09 Mar 2017 18:03:57 +0300] rev 1659
add hotkeys to open recent projects
For simplicity only last 9 projects are saved.
Alt-F, R, 1 - to open last opened project
Alt-F, R, 2 ...
...
Alt-F, R, 9 ...
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 09 Mar 2017 17:29:17 +0300] rev 1658
fix twice shown error message box, when wrong non-valid IEC identifier entered
It happens when non-valid name for variable name or name of field in
structure entered. This issue is described in details here:
http://trac.wxwidgets.org/ticket/16333
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Thu, 09 Mar 2017 15:35:19 +0300] rev 1657
apply constraints to names for tasks and task instances in resource configuration
The same rules as for IEC identifiers are applied.
- no non-lating characters, ...
- no IEC keywords
- check for duplicate names in resource configuration
closes #19
PaulBeltyukov [Thu, 09 Mar 2017 13:01:28 +0500] rev 1656
Fix russian translation