Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 14 Dec 2016 12:44:30 +0300] rev 1605
fix issue that in Debug mode LD instance doesn't show correctly its state after
continuation of FBD_Connector.
Previously state signals doesn't propogate through FBD_Connector.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 14 Dec 2016 12:36:04 +0300] rev 1604
fix issue with task rename if "Name" column label is translated into
other language
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 14 Dec 2016 12:31:06 +0300] rev 1603
fix issue with compiling SFC POU with non-connected transition (type "connection")
Sergey Surkov <surkovsv93@gmail.com> [Tue, 13 Dec 2016 17:47:34 +0300] rev 1602
fix bug with recent projects menu, remove path to the project from menu, if project directory doesn't exist
Sergey Surkov <surkovsv93@gmail.com> [Tue, 13 Dec 2016 17:40:03 +0300] rev 1601
fix bug with empty directories in recent projects menu
remove path to a project from recent projects menu, if project directory is empty
Sergey Surkov <surkovsv93@gmail.com> [Mon, 12 Dec 2016 14:29:40 +0300] rev 1600
fix list of recent projects in File menu, add path to current project after Save As
Sergey Surkov <surkovsv93@gmail.com> [Thu, 08 Dec 2016 17:54:43 +0300] rev 1599
by default init input and output in step sfc block, and output for initial step sfc block
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 19:28:13 +0300] rev 1598
update PLC status after initialization
This is necessary especially if existed PLC program is loaded, but PLC
is not started automatically. In this case taskbar icon shows that PLC
isn't empty.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 19:25:58 +0300] rev 1597
always load existing PLC program from the working directory
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 19:24:16 +0300] rev 1596
stop PLC before unloading
This fixes segmentation fault if service was quit without stopping it.
It has happened if Beremiz service was quit using taskbar icon or by
closing Beremiz IDE (in case of autostarted local service).
In second case to trigger the bug following step has to be done:
1. Open Beremiz IDE
2. Open project, compile and connect to LOCAL:// runtime
3. Transfer and start the PLC program
4. Open other project without disconneting the PLC runtime
5. Close Beremiz IDE
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:32:34 +0300] rev 1595
add internatialization support for Beremiz_service.py
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:25:37 +0300] rev 1594
fix issue with changing annonced Pyro service name via taskbar icon
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:23:59 +0300] rev 1593
don't crash on trying to change IP interface for Beremiz_service using taskbar icon if IP wasn't previously
By default IP is not set (None) and service listen only on localhost interface.
Andrey Skvortsov <andrej.skvortzov@gmail.com> [Wed, 07 Dec 2016 18:15:04 +0300] rev 1592
start/stop from taskbar icon only if PLC is stopped/started