- Nevow based web interface now show simple Log message sending form for basic runtime, and allow extensions to add their own web settings. nevow_service_rework 2018-07-04, by Edouard Tisserant
- Now, runtime extensions should be able to add their own settings to web configuration interface. nevow_service_rework 2018-06-22, by Edouard Tisserant
- Embrio of setting form, just to test nevow_service_rework 2018-06-22, by Edouard Tisserant
- #2486 Exception if custom protocol options are wrong. #2486 2018-06-05, by dporopat
- #2486 ExposedCalls with register options as a dictionary. #2486 2018-05-18, by dporopat
- #2486 Renaming functions. #2486 2018-05-14, by dporopat
- #2486 Reconnect funtion in SaveWampClientConf function. #2486 2018-05-14, by dporopat
- #2486 Modified reconnect function. Added 'active' parameter to wampconf.json file. #2486 2018-05-09, by dporopat
- #2486 Adding reconnect funtion to WampClient. Global TransportFactory not needed anymore. #2486 2018-04-19, by dporopat
- #2486 Added global TransportFactory, needed in WebInterface reconnecting function. #2486 2018-04-18, by dporopat
- #2486 WampClient needs pyro.plcobj before registration calls. #2486 2018-04-18, by dporopat
- #2486 Fix if protocol, register options are not present in wapmconf.json file. #2486 2018-04-11, by dporopat
- #2486 Added ExposedProgressCalls list using details argument for registration progress calls. #2486 2018-04-10, by dporopat
- #2486 Unnecessary variable removed. #2486 2018-04-10, by dporopat
- #2486 Added option to use websocket register options. Added function getValidOptins to read options from wampconf.json. #2486 2018-04-10, by dporopat
- #2486 Added option to use websocket protocol options. #2486 2018-04-09, by dporopat
- #2486 Updated wamp test project to work with the latest Crossbar version. #2486 2018-03-27, by dporopat
- #2486 Reset delay function added. It resets the delay and the retry counter on reconnect. #2486 2018-03-19, by dporopat
- merge 2018-06-23, by Edouard Tisserant
- merge 2018-06-23, by Edouard Tisserant
- Fix compilation warning/error: comparison between signed and unsigned integer expressions [-Werror=sign-compare] 2018-06-18, by Andrey Skvortsov
- merge 2018-06-18, by Andrey Skvortsov
- WxGlade HMI extension now does only instanciate wx object who's name match extension's name. If no object match the name and no code is provided in 'start' user python code section, then a warning is issued 2018-06-15, by Edouard Tisserant
- BACnet : ensure that Init did happen before continuing with PLC startup. 2018-06-13, by Edouard Tisserant
- Update list of files with strings for i18n and templates for translations 2018-06-15, by Andrey Skvortsov
- Add small contributing document with information about codestyle checking 2018-06-15, by Andrey Skvortsov
- Add argument to set list of source files to check 2018-06-15, by Andrey Skvortsov
- check_source.sh: handle case if there are no files to check 2018-06-09, by Andrey Skvortsov