tests/syntax/identifier/identifier_as_program.test
author Mario de Sousa <msousa@fe.up.pt>
Fri, 17 Aug 2012 19:03:13 +0100
changeset 624 c2546c6e0cfa
parent 108 f9e001952488
permissions -rwxr-xr-x
Moving function to correct location (formating only).
(* Test whether the keyword XXXX may be used as an identifier for:
 * Program identifier
 *
 * The XXXX names in the following code are merely a placeholder.
 * They will be replaced by several identifiers before actual testing
 * of the compiler.
 *)

(* The identifiers that will replace the XXXX
 * must be placed on a line starting with #
 * All identifiers preceded by # are ignored!
 * The identifier list must be placed inside an IEC 61131-3 comment.
 *)
(* This file is specific for identifiers identical to IL operators.
 *  See the note following the identifier list
 *)
(*
#IL_operators ANDN CAL CALC CALCN CD CLK CU IN JMP JMPC JMPCN LD LDN ORN PT PV R R1 RET RETC RETCN S S1 ST STN XORN
#SFC_qualifiers D DS L N P #R #S SD SL
     NOTE: R and S are identical to IL operators!!
#Task_initialisers PRIORITY SINGLE INTERVAL
*)

(* NOTE: The identifier as a variable test has some special cases.
 *       Namely, when using IL operators as variable names.
 *       Even though the syntax of the IL language would not result
 *       in ambiguities in the above case, our parser does not currently
 *       allow the use of variables (with names identical to IL
 *       operators) within IL code.
 *
 *       The following test code must therefore consider two possibilities:
 *        - if the identifier under test is an IL operator
 *        - if the identifier under test is not an IL operator
 *)






PROGRAM XXXX
VAR_INPUT
  a_1 : BOOL;
END_VAR
  LD a_1
END_PROGRAM





CONFIGURATION config1
 TASK fast(PRIORITY := 4);
 PROGRAM P1 WITH fast:
       XXXX(a_1 := TRUE);
END_CONFIGURATION




(* Checking whether the use of XXXX will confuse any other
 * normal and correct IL or ST code.
 *)
{#include "basic_code.test" }