AnnexF/weigh_st.txt
author mjsousa
Sat, 05 Jul 2014 13:57:39 +0100
changeset 901 6a3964be6a29
parent 0 fb772792efd1
permissions -rwxr-xr-x
Update build/compile instructions to reflect the fact that autoconf needs to be executed.
FUNCTION WEIGH : WORD     (* BCD encoded *)
  VAR_INPUT  (* "EN" input is used to indicate "scale ready" *)
    weigh_command : BOOL;
    gross_weight : WORD ; (* BCD encoded *)
    tare_weight : INT ;
  END_VAR
(* Function Body *)
IF weigh_command THEN
  WEIGH := INT_TO_BCD (BCD_TO_INT(gross_weight) - tare_weight);
END_IF ;

END_FUNCTION                     (* Implicit "ENO" *)