stage3/TODO
author Mario de Sousa <msousa@fe.up.pt>
Tue, 07 Feb 2012 17:40:19 +0000
changeset 433 1355adcdad58
parent 413 a9d377c4987a
permissions -rw-r--r--
Add, to types symbol table, string datatypes with limited length (my_string_type: STRING[33]) (Thanks Andreas!)


 Things that we must still check for in stage 3:


1) Handling of CONSTANTs:

 1.a) "Any program organization unit attempts to modify the value of a variable that has been declared with the CONSTANT qualifier;"
 1.b) From table 16.a "The CONSTANT qualifier shall not be used in the declaration of function block instances as described in 2.5.2.1."