Updated NEWS.
--- a/NEWS Thu Sep 13 10:56:51 2007 +0000
+++ b/NEWS Thu Sep 13 11:07:19 2007 +0000
@@ -6,6 +6,15 @@
Changes in version 1.3.1:
+* Improved EoE handling: Avoided skipping of datagrams and release lock
+ while processing.
+* Added some statistics to the datagram structure.
+* Master state machine clears all station addresses with a broadcast datagram
+ before setting them.
+* Added --enable-eoe conditional.
+* Minor extensions of the master info file.
+* Improved handling of unexpected working counters.
+* Create network interfaces for EoE devices with alias as eoeXaY.
* Fixed problems on big-endian systems.
* Added documentation on how to set up an EoE network.