fp@1877: /******************************************************************************
fp@1877:  *
fp@1877:  *  $Id$
fp@1877:  *
fp@1877:  *  Copyright (C) 2006-2008  Florian Pose, Ingenieurgemeinschaft IgH
fp@1877:  *
fp@1877:  *  This file is part of the IgH EtherCAT Master.
fp@1877:  *
fp@1877:  *  The IgH EtherCAT Master is free software; you can redistribute it and/or
fp@1877:  *  modify it under the terms of the GNU General Public License version 2, as
fp@1877:  *  published by the Free Software Foundation.
fp@1877:  *
fp@1877:  *  The IgH EtherCAT Master is distributed in the hope that it will be useful,
fp@1877:  *  but WITHOUT ANY WARRANTY; without even the implied warranty of
fp@1877:  *  MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the GNU General
fp@1877:  *  Public License for more details.
fp@1877:  *
fp@1877:  *  You should have received a copy of the GNU General Public License along
fp@1877:  *  with the IgH EtherCAT Master; if not, write to the Free Software
fp@1877:  *  Foundation, Inc., 51 Franklin St, Fifth Floor, Boston, MA  02110-1301  USA
fp@1877:  *
fp@1877:  *  ---
fp@1877:  *
fp@1877:  *  The license mentioned above concerns the source code only. Using the
fp@1877:  *  EtherCAT technology and brand is only permitted in compliance with the
fp@1877:  *  industrial property and similar rights of Beckhoff Automation GmbH.
fp@1877:  *
fp@1877:  *****************************************************************************/
fp@1877: 
fp@1877: /**
fp@1877:    \file
fp@1877:    EtherCAT SoE errors.
fp@1877: */
fp@1877: 
fp@1877: /*****************************************************************************/
fp@1877: 
fp@1877: #include "globals.h"
fp@1877: 
fp@1877: /*****************************************************************************/
fp@1877: 
fp@1877: /** SoE error codes.
fp@1877:  */
fp@1877: const ec_code_msg_t soe_error_codes[] = {
fp@1877:     {0x1001, "No IDN"},
fp@1877:     {0x1009, "Invalid access to element 1"},
fp@1877:     {0x2001, "No name"},
fp@1877:     {0x2002, "Name transmission too short"},
fp@1877:     {0x2003, "Name transmission too long"},
fp@1877:     {0x2004, "Name cannot be changed, read only"},
fp@1877:     {0x2005, "Name is write protected at this time"},
fp@1877:     {0x3002, "Attribute transmission too short"},
fp@1877:     {0x3003, "Attribute transmission too long"},
fp@1877:     {0x3004, "Attribute cannot be changed, read only"},
fp@1877:     {0x3005, "Attribute is write protected at this time"},
fp@1877:     {0x4001, "No unit"},
fp@1877:     {0x4002, "Unit transmission too short"},
fp@1877:     {0x4003, "Unit transmission too long"},
fp@1877:     {0x4004, "Unit cannot be changed, read only"},
fp@1877:     {0x4005, "Unit is write proteced at this time"},
fp@1877:     {0x5001, "No minimum input value"},
fp@1877:     {0x5002, "Minimum input value transmission too short"},
fp@1877:     {0x5003, "Minimum input value transmission too long"},
fp@1877:     {0x5004, "Minimum input value cannot be changed, read only"},
fp@1877:     {0x5005, "Minimum input value is write protected at this time"},
fp@1877:     {0x6001, "No maximum input value"},
fp@1877:     {0x6002, "Maximum input value transmission too short"},
fp@1877:     {0x6003, "Maximum input value transmission too long"},
fp@1877:     {0x6004, "Maximum input value cannot be changed, read only"},
fp@1877:     {0x6005, "Maximum input value is write protected at this time"},
fp@1877:     {0x7002, "Operation data value transmission too short"},
fp@1877:     {0x7003, "Operation data value transmission too long"},
fp@1877:     {0x7004, "Operation data value cannot be changed, read only"},
fp@1877:     {0x7005, "Operation data value is write protected at this time"},
fp@1877:     {0x7006, "Operation data value is smaller than the minimum input value"},
fp@1877:     {0x7007, "Operation data value is greater than the minimum input value"},
fp@1877:     {0x7008, "Invalid operation data"},
fp@1877:     {0x7009, "Operation data is write protected by a password"},
fp@1877:     {0x700A, "Operation data is write protected"},
fp@1877:     {0x700B, "Invalid indirect addressing"},
fp@1877:     {0x700C, "Operation data is write protected due to other settings"},
fp@1877:     {0x700D, "Reserved"},
fp@1877:     {0x7010, "Procedure command already active"},
fp@1877:     {0x7011, "Procedure command not interruptible"},
fp@1877:     {0x7012, "Procedure command is at this time not executable"},
fp@1877:     {0x7013, "Procedure command not executable"},
fp@1877:     {0x7014, "No data state"},
fp@1877:     {0x8001, "No default value"},
fp@1877:     {0x8002, "Default value transmission too long"},
fp@1877:     {0x8004, "Default value cannot be changed, read only"},
fp@1877:     {0x800A, "Invalid drive number"},
fp@1877:     {0x800B, "General error"},
fp@1877:     {0x800C, "No element addressed"},
fp@1877:     {}
fp@1877: };