examples/SillySlave/README
author greg
Wed, 26 Mar 2008 11:14:09 +0100
changeset 433 df0bdfa1e463
parent 400 7d845f5d730c
permissions -rw-r--r--
added Gnosis_Utils tar.gz file
SillySlave example for CANfestival

Its purpose is only to check if the selected
driver works at least a minimum. The PC running this demo
must be connected through CAN bus to a working master that 
recognizes the slave nodeId. The slave should be configured
by the master, then switched to operative. After that, when
the master sends a SYNC, the slave answers with PDO1, 
containing an integer that increments each time it is sent.

Please have a look to main.h to tune the master and slave node IDs

It's all. Enjoy it.
GMB
jan 17,2008