NativeLib.xml
author Edouard Tisserant
Wed, 01 Jul 2020 10:36:20 +0200
changeset 2686 703ebf57508a
parent 1050 56bef276055e
permissions -rw-r--r--
Modbus and Bacnet websettings : Rename variables and functions to avoid name collisions.

Websettings for modbus and bacnet are now passed to runtime as python files loaded (execfile) at init of PLCObject with the same globals.
Because if this, same names used in previously different modules now colide.
<?xml version="1.0" encoding="UTF-8"?>
<project xmlns="http://www.plcopen.org/xml/tc6.xsd"
         xsi:schemaLocation="http://www.plcopen.org/xml/tc6.xsd"
         xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
         xmlns:xhtml="http://www.w3.org/1999/xhtml">
  <fileHeader companyName="Unknown"
              productName="Unnamed"
              productVersion="1"
              creationDateTime="2013-01-29T14:01:00"/>
  <contentHeader name="Unnamed"
                 modificationDateTime="2013-02-26T15:59:13">
    <coordinateInfo>
      <fbd>
        <scaling x="0" y="0"/>
      </fbd>
      <ld>
        <scaling x="0" y="0"/>
      </ld>
      <sfc>
        <scaling x="0" y="0"/>
      </sfc>
    </coordinateInfo>
  </contentHeader>
  <types>
    <dataTypes>
      <dataType name="LOGLEVEL">
        <baseType>
          <enum>
            <values>
              <value name="CRITICAL"/>
              <value name="WARNING"/>
              <value name="INFO"/>
              <value name="DEBUG"/>
            </values>
          </enum>
        </baseType>
        <initialValue>
          <simpleValue value="INFO"/>
        </initialValue>
      </dataType>
    </dataTypes>
    <pous>
      <pou name="LOGGER" pouType="functionBlock">
        <interface>
          <inputVars>
            <variable name="TRIG">
              <type>
                <BOOL/>
              </type>
            </variable>
            <variable name="MSG">
              <type>
                <string/>
              </type>
            </variable>
            <variable name="LEVEL">
              <type>
                <derived name="LOGLEVEL"/>
              </type>
              <initialValue>
                <simpleValue value="INFO"/>
              </initialValue>
            </variable>
          </inputVars>
          <localVars>
            <variable name="TRIG0">
              <type>
                <BOOL/>
              </type>
            </variable>
          </localVars>
        </interface>
        <body>
          <ST>
<![CDATA[IF TRIG AND NOT TRIG0 THEN
{{
 LogMessage(GetFbVar(LEVEL),(char*)GetFbVar(MSG, .body),GetFbVar(MSG, .len));
}}
END_IF;
TRIG0:=TRIG;
]]>
          </ST>
        </body>
      </pou>
    </pous>
  </types>
  <instances>
    <configurations/>
  </instances>
</project>